基础医学与临床 ›› 2026, Vol. 46 ›› Issue (7): 895-903.doi: 10.16352/j.issn.1001-6325.2026.07.0895

• 研究论文 • 上一篇    下一篇

理论光谱在小鼠骨髓细胞光谱流式细胞测量术中的应用

李卓, 刘雪会, 李静, 范宏, 樊化林, 吕湘*   

  1. 中国医学科学院北京协和医学院 基础医学研究所 病理生理学系 疑难重症及罕见病全国重点实验室,北京 100005
  • 收稿日期:2026-03-30 修回日期:2026-05-19 发布日期:2026-06-23
  • 通讯作者: *lvxiang@pumc.edu.cn
  • 基金资助:
    国家自然科学基金(82570165);疑难重症及罕见病全国重点实验室自主课题(2025-I-PY-004);中国医学科学院创新工程攻关项目(2025-I2M-KJ-017)

Application of theoretical spectra in spectral flow cytometry of mouse bone marrow cells

LI Zhuo, LIU Xuehui, LI Jing, FAN Hong, FAN Hualin, LYU Xiang*   

  1. State Key Laboratory of Complex, Severe, and Rare Diseases, Department of Pathophysiology, Institute of Basic Medical Sciences, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing 100005, China
  • Received:2026-03-30 Revised:2026-05-19 Published:2026-06-23
  • Contact: *lvxiang@pumc.edu.cn

摘要: 目的 探索光谱流式细胞测量术(流式)中理论光谱替代单染对照的可行性与局限性,并对自发荧光导致的理论光谱与单染对照实测光谱偏差,提出参考光谱优化策略。方法 对小鼠骨髓单染样本进行多平台光谱流式分析,以余弦相似度评估理论光谱与单染实测光谱的一致性;针对受自发荧光干扰的单染样本,采用自发荧光相对均质的细胞子集生成参考光谱,并分析其对解混结果的改善作用。结果 11种抗体-荧光素/荧光染料中,5种在两平台的实测光谱均与理论光谱余弦相似度≥0.90,有望替代单染对照;不匹配光谱可表现为检测条件相关的光谱偏移,或在部分样本中表现为与自发荧光干扰相关的异常参考光谱。预设子集策略可校正自发荧光异质性引起的参考光谱异常,显著降低了小鼠骨髓细胞光谱解混溢漏误差。结论 理论光谱可作为参考光谱评估和校正的有效工具,并有望部分替代单染对照;预设子集策略可改善自发荧光所致参考光谱偏差,提升光谱解混准确度。

关键词: 光谱流式细胞测量术, 理论光谱, 参考光谱, 自发荧光, 预设子集策略

Abstract: Objective To investigate the feasibility and limitations of theoretical spectra applied as substitutes for single-stained controls in spectral flow cytometry, and to propose a reference-spectrum optimization strategy for correcting deviations between theoretical and experimentally measured spectra caused by auto-fluorescence. Methods Mouse bone marrow single-stained samples were collected and analyzed by multi-platform spectral flow cytometry. Cosine similarity was used to evaluate the consistency between theoretical spectra and experimentally measured spectra. For single-stained samples affected by autofluorescence, reference spectra were generated from cell subsets with relatively homogeneous auto-fluorescence, and their effects on performance were assessed. Results Among eleven antibody-fluorochromes/fluorescent dyes, five of them showed cosine similarity values of 0.90 or higher between measured and theoretical spectra on both platforms, which suggested that they might serve as alternatives to single-stained controls. Spectral mismatches manifested either as spectral shifts related to detection conditions or, in a subset of samples, as abnormal reference spectra associated with auto-fluorescence interference. The subset strategy corrected abnormal reference spectra caused by auto-fluorescence heterogeneity and significantly reduced unmixing spillover errors in mouse bone marrow cells. Conclusions Theoretical spectra can serve as effective tools for evaluating and correcting reference spectra and may partially replace single-stained controls. The subset strategy can reduce reference-spectrum bias caused by autofluorescence and improve the accuracy of spectral unmixing.

Key words: spectral flow cytometry, theoretical spectra, reference spectra, autofluorescence, subset strategy

中图分类号: